Helping Folks Since 1975 & 11 Years on the Web!

|
| 
DSP Inlet Valve Assembly 0512222
|
Fits the Following Pumps |
| Wagner |
Amspray |
SprayTech
Apex |
Pro Force |
Krebs |
| 9135 / 9140 |
1400 |
1420 |
PF23 |
2015 |
| 9146 |
|
|
|
|
| 9150 |
1500/1550 |
1620 |
|
|
| |
|
|
PF25 |
|
| |
|
|
|
|
This is the complete inlet assembly, including all parts as shown in the black and white image to the right. We include the exploded breakdown to help a customer reassemble the inlet assembly in case it was taken apart for cleaning or such. However NO individual parts are available for the inlet assembly. So if you do take it apart for cleaning, be careful not to loose any parts; or you will have to purchase the whole assembly.
Question: How do you know when to replace this part?
Answers: 1: If you lost any parts inside the assembly you must replace the assembly. (Common part to loose is the ball, which the ball CAN NOT come out on it’s own. If it is lost this means the user took the assembly apart and lost the ball.)
2: A inlet will eventually wear out and need replacing. A worn inlet will give you similar symptoms as a worn packing. So it is sometimes hard to tell when to replace the inlet assembly. The basic way to tell is if the pump is priming, but will not build up full pressure. And you know that the packing is good (and that the upper and lower ball is not stuck) then replace the inlet assembly.
| |